Safety Inspections

All our safety inspections comply with Australian Standards:

AS4084-1993 Steel Storage Racking

AS4084-1993: Covers all static racking with the exception of drive in and drive through racking as well as cantilever and mobile racking.

Section 9.2 Inspections. Inspections shall be carried out on a regular basis, and at least once every 12 months to: 

  • Ensure that safe working loads are adhered to.
  • Ensure that the racking installation has not been altered. A copy of the load application and configuration drawings shall be retained for this purpose.
  • Ensure the correct application and use of the equipment.
  • Examine connectors for deformation or signs of cracking at the welds.
  • Examine for any dislocation and deformation of sections and connections for uprights and beams.
  • Examine the extent of damage due to impact in the racking installation.
  • Examine the out of plumb of the racking.

These Audits usually comprise of a written report with two sections:

  1. Rack specifications list & load ratings for each rack
  2. Damage and non-compliance list detailing:

This list is colour coded so that each problem can be categorised into four groups depending on the severity or hazard risk factor of the problem

  1. Red category – immediate action
  2. Orange category – do not use until rectified
  3. Blue category – routine problem
  4. Green category – recommendation only

On satisfactory completion of repairs a Certificate of Compliance will be issued.

2a: This section can be given to the manufacturer/repairer so that they may quote on the problems that need addressing, alternatively, Racking Audits Australia can quote for these repairs/modifications for you.

2b: If this is the first visit a Rack location (plan view) drawing will also be included. This can also be given to your choice of repairer to aid in the rectification process.